| Brand Name: | DLX |
| Model Number: | Thermocouple Bare Wire |
| MOQ: | 5kg |
| Payment Terms: | L/C,D/A,Western Union,T/T,MoneyGram,D/P,MoneyGram |
| Supply Ability: | 300 tons per month |
High-quality thermocouple wire designed for extreme heat applications with precise temperature measurement capabilities.
| Application | Temperature sensor wire |
|---|---|
| Conductor Material | Other |
| Conductor Type | Solid |
| Insulation Material | PVC |
| Rated voltage | / |
| Place of Origin | Jiangsu, China |
|---|---|
| Brand Name | DLX |
| Model Number | S type |
| Type | Bare |
| Product name | Thermocouple Wire |
| Color | Customer's Requirement |
| Conductor | NiCr |
| Material | NiCr |
| Size | Customized Size |
| Delivery time | 15~20days |
|---|---|
| Packaging Details | Plastic film or waterproof woven bag inside, wire packed in spool put into carton, coil wire or strip wire put into wooden case |
| Port | ShangHai NingBo Customized |
| Selling Units | Single item |
| Single package size | 25X25X12 cm |
| Single gross weight | 2.000 kg |
1000000 Kilogram/Kilograms per Month
There are multiple types and grades of thermocouple wire. Each type of thermocouple wire has a specific combination of metal alloys. This combination is what defines the type of thermocouple. Thermocouple grade wire is used to manufacture thermocouple probes. Thermocouple grade wire is normally used for the junction and inside the stem sheath.
| ASTM | (American Society for Testing and Materials) E 230 |
|---|---|
| ANSI | (American National Standard Institute) MC 96.1 |
| IEC | (European Standard by the International Electrotechnical Commission 584)-1/2/3 |
| DIN | (Deutsche Industrie Normen) EN 60584 -1/2 |
| JIS | (Japanese Industrial Standards) C 1602 - C 1610 |
| GOST | (Unification of the Russian Specifications) 3044 |